©Meyertech Ltd 2007
T
el: +44 (0)161 628 8406 Email:
[email protected]DS0702-1.2 ZVR 130+www.meyertech.co.uk/zonevu.htm
ZoneVu ZVR 130+
TelemeTRy ReceiVeR
Meyertech Ltd. Ofce Block One, Southlink Business Park, Oldham OL4 1DE
The purpose of this data sheet is to provide product information on Meyertech products. The information in this data
sheet is believed to be accurate and reliable. However, no responsibility or liability is assumed by Meyertech Limited
for its use, or for any infringement of patents or other rights of third parties, which may result from its use. No li-
cense is granted by implication or otherwise under any patent or other rights of Meyertech Limited. Meyertech are
committed to continuous product development and therefore reserve the right to change specication without notice.
ordering inFormation
ZVR-130+RS422-PCB ZoneVu advanced telemetry receiver PCB with RS422 SIP. Functions - aux 1, aux 2, global support,
camera fail, 3 x alarm contacts, static caption, remote conguration, auto-timeout facilities, alarm
reporting, upload/download of conguration data, integrated digital camera conguration. Designed
to locate inside camera housing. RS485 half-duplex control. On-board self-test diagnostics and tam-
per alarm.
ZVR-130-PSU ZVR-130 PSU 230/24V AC 6VA
aPPlications
ANPR
Ideal for ANPR applications as control of
the camera is provided through the ZVR-
130 allowing settings for functions such as
white balance, back light compensation,
gain control and shutter speed to be easily
recongured by the operator.
Where provided by the camera, two different
modes can be set up allowing the camera
to be quickly switched between ANPR and
normal use or day and night operation.
All of this can be done from the comfort of
the control room via Meyertech’s ZoneVu
ZVK-77D keyboard or Fusion GUI software
management systems at the press of a
button.
Wash/Wipe
Perfect for areas where cleaning is an issue.
Normally external static cameras require a
monthly visit from a maintenance team to
keep the viewing aperture clean and free
from grease and grime.
In many cases this requires a lift or ladder
to access the camera housing, however
with the addition of the ZVR-130 telemetry
receiver wash and wipe facilities can be
added to the camera with the reservoir being
relled from a more accessible position such
as the bottom of the column.
In addition, the level of the reservoir can
be monitored through the ZVR-130’s alarm
inputs, thereby reducing maintenance visits
& costs.
sPeciFication
Enclosure PCB format – Universal mounting bracket open frame
which can be installed either vertically or horizontally.
Dimensions PCB mounted on universal bracket – W175mm D87mm
H39mm
Weight 300g including universal bracket
Power input 24V AC +/- 10% 50-60Hz 250mA (Excluding 12V DC
output). 12V DC 180mA operating, 220mA power up
surge
12V DC Output 750mA at 12V DC +/- 15%. Not available from 12V DC
input
Temperature Storage -20
o
to +60
o
C; Operational 0
o
to +50
o
C; Humidity
10% to 95% non-condensing
ZoneVu Network Port RS422/RS485 half duplex or simplex
Serial Integration
Port
RS422 / RS485 – half duplex or full duplex
Alarm Inputs Contact type – Tamper and two unassigned. All N/O
or N/C plus alarm common. Other – Video loss sync.
Monitoring
Diagnostic LED’s +12V and CPU (Heartbeat), ZoneVu network
communications Tx and Rx and Serial Integration Port Tx
and Rx.
OSD Camera captions – conguration menus – alarm captions
– command captions. Two columns 14 characters per
column, 16 rows, with greyscale shade selection and
individual letter borders
Functions Connectors Miniature Klippon 2-part 3 to 8 way.
Video Connectors BNC 75R
Video Inputs 1V p-p 75R terminated. PAL CCIR
Video Outputs 1V p-p 75R impedance. PAL CCIR
Camera Power +12VDC +/- 1V 9W maximum
Relay 1 NC or NO volt free contacts 1A 30V AC/DC
Relay 2 NC or NO volt free contacts 1A 30V AC/DC
Address Range 1 – 4096
Static Caption 14 Characters
Alarm Text 14 Characters x 3 Alarms
MTBF 56,502 Hours