Meyertech ZoneVu 328 Series Technické informace Strana 46

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 58
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 45
ZSC - 250 Issue 1.0 ©Meyertech Ltd 2006 Tel: +44 (0)161 628 8406 Email: [email protected]
Meyertech Ltd. Ofce Block One, Southlink Business Park, Oldham OL4 1DE
The purpose of this data sheet is to provide provisional product information on Meyertech products. The information in
this data sheet is believed to be accurate and reliable. However, no responsibility or liability is assumed by Meyertech
Limited for its use, or for any infringement of patents or other rights of third parties, which may result from its use. No
license is granted by implication or otherwise under any patent or other rights of Meyertech Limited. Meyertech are
committed to continuous product development and therefore reserve the right to change specication without notice.
orDering inFormation
ZSC-250 ZoneVu Site Gateway module ZSC-250SDV SDK version of the ZoneVu ZSC-250.
Includes Development leads,
PSU and Manual.
ZSC-PSU ZoneVu ZSC-250 PSU. ZoneVu-SDK-
SC
ZoneVu Software development support
contract for OEM’s. 12-month contract.
Provides telephone and email develop-
ment support from Meyertech engineers.
ZoneVu-SDK Full ZoneVu software developers kit, includes ZSC-
250SDV, Development leads, Manual, ZoneVu Op-
erational Protocol document, Meyertech CaNDA,
12-month ZoneVu-SDK Support Contract.
M-CaNDA-ZPD Meyertech CaNDA and Protocol Docu-
ment.
ZoneVu Site Gateway Module ZSC - 250
speciFication
Parameter Value
Temperature Storage –20º to +60ºC. Operational 0º to
+50ºC. Humidity 10% to 95% non-con-
densing
Enclosure Fully enclosed Euro rack. Colour - Black
Dimensions 19” rack by 1U by 142mm
Weight 660g
Power (External PSU - supplied) 99 to 264VAC
50Hz (ZSC-PSU direct +12VDC)
Power Consump-
tion
Less than 6W
ZoneVu Port RS422 half duplex
PC 1 Port RS232 duplex. Site gateway 1
PC 2 Port RS232 duplex. Site gateway 2
PC 3 Port RS232 duplex. Site gateway 3
Conguration Congurable via Mpower ZoneVu soft-
ware conguration tool. PC required with
RS232 port.
Diagnostics / Sta-
tus indicators
Power present LED, CPU heartbeat LED,
PC1 port, PC2 port, PC3 port, ZoneVu port
LED’s
Connector-Power Low voltage DC power connector
Connector-PC 1, PC
2 and PC 3 ports
9-way D type female
Connector-ZoneVu
port
2-part Klippon type 6-way
Development leads
(ZSC-250SDV only)
3 x RS232 development 3m leads. 1 x
ZoneVu Network 5m lead
Protocol (ZSC-
250SDV only)
ZoneVu Half-duplex full protocol parsing
MTBF 70,000 Hours
local site support
Support System Parameter
Cameras - video 4,096. Installed Site Master dependant
Monitors 2,048. Installed Site Master dependant
Cameras - con-
trol
4,096. Installed Site Master dependant
PC Devices 32. Achieved by cascading ZSC-250
modules
Peripheral CCTV
Devices
90. Installed Site Master dependant
Matrices ZVS3, ZVS2, ZVM-328, ZVM-164.
Installed Site Master dependant
Re-mapped
camera ranges
Yes. As per ZSC-1000
Camera control
priority
Full hierarchal prioritised implementation
Alarm reporting Yes
Sequence pat-
terns
Yes. As per ZSC-1000
inter site support
Inter-site management requires a ZSC-1000 to be installed
at the site the ZSC-250 is installed.
Support System Parameter
Sites 100 sites, 16 via ZSC-1000
inter-site port. 84 dial-up sites.
Inter-site video Yes
Inter-site cam-
era control
Yes
Matrix Input
Trunks
Yes. As per ZSC-1000
Monitor Input
Trunks
Yes. As per ZSC-1000
Output Trunks Yes. As per ZSC-1000
Zobrazit stránku 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 57 58